Response Stage: Trillium-240 Generation 1 PZ
| Name: | Trillium-240 Generation 1 PZ | Correction: | |
|---|
| Stage Index: | 1 | Sample Offset: | 0.0 |
|---|
| Stage Type: | Poles & Zeros | Decimation: | 1.0 |
|---|
| Input Units: | M/S | Input Sample Rate: | |
|---|
| Output Units: | V | Gain: | 1196.9000000 |
|---|
| Transfer Function Type: | Continuous | Gain Frequency: | 1.0 |
|---|
| Delay: | 0 s | Symmetry: | None |
|---|
Poles & Zeros
There areShowing 1 of 17 poles & zeros.
| Type |
Index |
Value |
Action |
| Pole |
1 |
-0.01813+0.01803i |
|
| Pole |
2 |
-0.01813-0.01803i |
|
| Pole |
3 |
-84.40000+0.00000i |
|
| Pole |
4 |
-180.20000+224.40000i |
|
| Pole |
5 |
-180.20000-224.40000i |
|
| Pole |
6 |
-725.00000+0.00000i |
|
| Pole |
7 |
-1060.00000+0.00000i |
|
| Pole |
8 |
-4300.00000+0.00000i |
|
| Pole |
9 |
-5800.00000+0.00000i |
|
| Pole |
10 |
-4200.00000+4600.00000i |
|
| Pole |
11 |
-4200.00000-4600.00000i |
|
| Zero |
1 |
0.00000+0.00000i |
|
| Zero |
2 |
0.00000+0.00000i |
|
| Zero |
3 |
-72.50000+0.00000i |
|
| Zero |
4 |
-163.30000+0.00000i |
|
| Zero |
5 |
-251.00000+0.00000i |
|
| Zero |
6 |
-3270.00000+0.00000i |
|